A review of the performance of different ventilation and airflow distribution systems in buildings G Cao, H Awbi, R Yao, Y Fan, K Sirén, R Kosonen, JJ Zhang Building and environment 73, 171-186, 2014 | 507 | 2014 |
Field-based study on the energy-saving effects of CO2 demand controlled ventilation in an office with application of energy recovery ventilators Y Fan, K Kameishi, S Onishi, K Ito Energy and buildings 68, 412-422, 2014 | 86 | 2014 |
Energy consumption analysis intended for real office space with energy recovery ventilator by integrating BES and CFD approaches Y Fan, K Ito Building and environment 52, 57-67, 2012 | 84 | 2012 |
Thermal, mechanical and chemical material removal mechanism of carbon fiber reinforced polymers in electrical discharge machining X Yue, X Yang, J Tian, Z He, Y Fan International Journal of Machine Tools and Manufacture 133, 4-17, 2018 | 73 | 2018 |
Integrated building energy computational fluid dynamics simulation for estimating the energy-saving effect of energy recovery ventilator with CO2 demand … Y Fan, K Ito Indoor and Built Environment 23 (6), 785-803, 2014 | 36 | 2014 |
Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model Y Fan, T Hayashi, K Ito Journal of Central South University 19, 633-638, 2012 | 25 | 2012 |
Optimization of indoor environmental quality and ventilation load in office space by multilevel coupling of building energy simulation and computational fluid dynamics Y Fan, K Ito Building Simulation 7 (6), 649-659, 2014 | 20 | 2014 |
Performance evaluation of different air distraction system on thermal uniformity and energy saving: A case study of a Japanese detached house Y Fan Indoor and Built Environment 28 (2), 186-194, 2019 | 9 | 2019 |
Energy conservation and thermal environment analysis of room air conditioner with intermittent supply airflow Y Fan, M Toyoshima, M Saito International Journal of Low-Carbon Technologies 13 (1), 84-91, 2018 | 8 | 2018 |
Mathematical and experimental analysis of the thermal effectiveness of an oscillating jet with side-to-side swing louvers in a cassette split type air conditioner Y Fan Indoor and Built Environment 29 (2), 240-254, 2020 | 6 | 2020 |
中規模オフィスビルを対象とした全熱交換器の空調消費電力削減効果に関する実測研究 : 第3報-全熱交換器モデルを介したCFDとBESの連成解析 Y FAN, K ITO 空気調和・衛生工学会 論文集 37 (180), 13-21, 2012 | 5 | 2012 |
Application of hydroturbine pump in water source heat pump drainage gravitational potential energy recovery system J Lu, Y Fan, J Song, H Tang, C Yu Indoor and Built Environment 19 (5), 546-554, 2010 | 5 | 2010 |
A TOPSIS optimization for the indoor thermal environment through oscillating airflow generated from a cassette split type air conditioner Y Fan Indoor and Built Environment 30 (8), 1200-1210, 2021 | 4 | 2021 |
ルームエアコン室内ファン断続制御の消費電力評価 Y FAN, M TOYOSHIMA, M SAITO 日本冷凍空調学会年次大会講演論文集 Proceedings of the JSRAE Annual …, 2018 | | 2018 |
CO_2 デマンド制御型換気装置のセンシング時間遅れに関する基礎実験と CFD 解析による検証 亀石圭司, 戸田悠太, 范芸青, 伊藤一秀 空気調和・衛生工学会 論文集 39 (211), 7-13, 2014 | | 2014 |
CO2 デマンド制御を組み込んだ熱交換型換気システムの性能評価 (第 6 報) CO2 濃度センシングの時間遅れに関する基礎実験 亀石圭司, 戸田悠太, 范芸青, 伊藤一秀 空気調和・衛生工学会大会 学術講演論文集 平成 26 年度大会 (秋田) 学術講演論文 …, 2014 | | 2014 |
CO2 デマンド制御を組み込んだ熱交換型換気システムの性能評価 (第 7 報) CO2 濃度センシングの時間遅れ検証実験に対応した CFD 解析 戸田悠太, 亀石圭司, 范芸青, 伊藤一秀 空気調和・衛生工学会大会 学術講演論文集 平成 26 年度大会 (秋田) 学術講演論文 …, 2014 | | 2014 |
Integration of Dynamic Airflow and Energy Simulation for optimized ventilation design 范芸青 九州大学, 2013 | | 2013 |
J-57 CO_2ディマンド制御を組み込んだ熱交換型換気システムの性能評価 : (第2報)CO_2ディマンド制御を組み込んだBES-CFDの連成解析 范芸青, 伊藤一秀 空気調和・衛生工学会大会 学術講演論文集 3, 2012 | | 2012 |
J-56 CO2 ディマンド制御を組み込んだ熱交換型換気システムの性能評価:(第 1 報) 大学研究室スペースを対象とした実測概要と全熱交換器の現場性能 清弘宗一郎, 亀石圭司, 大西茂樹, 范芸青, 伊藤一秀 空気調和・衛生工学会大会 学術講演論文集 平成 24 年, 3001-3004, 2012 | | 2012 |