Dose analyze of boron neutron capture therapy (BNCT) at skin cancer melanoma using MCNPX with neutron source from thermal column of Kartini Reactor S Rosidah, Y Sardjono, Y Sumardi Indonesian Journal of Physics and Nuclear Applications 2 (3), 111-123, 2017 | 7 | 2017 |
A design of boron neutron capture therapy for cancer treatment in Indonesia Y Sardjono, S Widodo, I Irhas, H Tantawy Indonesian Journal of Physics and Nuclear Applications 1 (1), 1-13, 2016 | 7 | 2016 |
Dosimetry of in vitro and in vivo trials in thermal column Kartini Reactor for Boron Neutron Capture Therapy (BNCT) facility by using MCNPX simulator code A Tesalonika, AW Harto, Y Sardjono, IM Triatmoko Indonesian Journal of Physics and Nuclear Applications 1 (2), 63-72, 2016 | 6 | 2016 |
Optimization of neutron collimator in the thermal column of Kartini research reactor for in vitro and in vivo trials facility of boron neutron capture therapy using MCNP-X … R Warfi, AW Harto, Y Sardjono, W Widarto Indonesian Journal of Physics and Nuclear Applications 1 (1), 54-62, 2016 | 5 | 2016 |
Basic principle application and technology of boron neutron capture cancer therapy (BNCT) utilizing Monte Carlo N Particle 5’s software (MCNP 5) with compact neutron generator … A Payudan, AN Aziz, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 1 (1), 20-33, 2016 | 5 | 2016 |
Double layer collimator for BNCT neutron source based on 30 MeV cyclotron B Bilalodin, K Kusminarto, A Hermanto, Y Sardjono, S Sunardi Indonesian Journal of Physics and Nuclear Applications 2 (3), 124-127, 2017 | 4 | 2017 |
Creative Environmental Energy Technology Assessment Hydroelectric Power Plant (Case Study of Wonogiri Reservoir) F Hidayani, Y Sardjono, C Fandeli, AR Rukmini Indonesian Journal of Physics and Nuclear Applications 2 (3), 101-110, 2017 | 2 | 2017 |
Optimization of Collimator Neutron Design for Boron Neutron-Capture Cancer Therapy (BNCT) Based Cyclotron 30 MeV A Payudan, A Haryadi, F Abdullatif Indonesian Journal of Physics and Nuclear Applications 2 (3), 128-136, 2017 | 2 | 2017 |
Internal Dose Analysis for Radiation Worker in Cancer Therapy Based on Boron Neutron Capture Therapy with Neutron Source Cyclotron 30 MeV Using Monte Carlo N Particle Extended … AS Wicaksono, AW Harto, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 2 (2), 91-100, 2017 | 2 | 2017 |
Calculation of Absorbed Dose Distribution for Breast Brachytherapy Simulation By CS-1 131Cs Seed and ADVANTAGETM 103Pd Seed Using Monte Carlo N Particle Extended Simulator FR Rahmat, M Mondjo, A Agung Indonesian Journal of Physics and Nuclear Applications 2 (2), 65-74, 2017 | 2 | 2017 |
Biological Evaluation of 99mTc-Kanamycin for Infection Imaging EM Widyasari, I Halimah, RJ Sugiharti, ME Sriyani, I Daruwati, I Iswahyudi, ... Indonesian Journal of Physics and Nuclear Applications 2 (1), 34-41, 2017 | 2 | 2017 |
The effect of thickness variation of beryllium target toward characteristics of neutron energy spectrum on cyclotrons HM-30 using MCNP-X S Yuniarti, A Haryadi, RF Abdullatif Indonesian Journal of Physics and Nuclear Applications 2 (3), 137-143, 2017 | 1 | 2017 |
Conceptual design of collimator at Boron Neutron Capture Therapy facility with 30 MeV cyclotron and target 9Be as neutron generator using Monte Carlo N-particle extended simulator P Isyan, AW Harto, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 2 (1), 47-53, 2017 | 1 | 2017 |
Analysis of Safety and Health of Radiation Officer at Pilot Plant BNCT S Soeparmi, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 2 (1), 42-46, 2017 | 1 | 2017 |
Assessment of Analytical Instrumentation for Boron Measurement in BNCT System IM Triatmoko, S Sutjipto Indonesian Journal of Physics and Nuclear Applications 2 (1), 20-33, 2017 | 1 | 2017 |
Boron Neutron Capture Therapy (BNCT) using Compact Neutron generator AD Susilowati, K Kusminarto, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 1 (2), 73-80, 2016 | 1 | 2016 |
Clinical trial design of Boron Neutron Capture Therapy on breast cancer using DD coaxial compact neutron generator as neutron source and Monte Carlo N-Particle simulation method R Pasaribu, K Kusminarto, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 1 (1), 34-43, 2016 | 1 | 2016 |
Design Collimator and Dosimetry of in Vitro and in Vivo Test Using MCNP-X Code S Yuniarti, Y Sardjono, B Bilalodin Indonesian Journal of Physics and Nuclear Applications 1 (1), 14-19, 2016 | 1 | 2016 |
Shield Modelling of Boron Neutron Capture Therapy Facility with Kartini Reactor’s Thermal Column as Neutron Source using Monte Carlo N Particle Extended Simulator MIMA Dwiputra, AW Harto, Y Sardjono, GS Wijaya Indonesian Journal of Physics and Nuclear Applications 1 (1), 44-53, 2016 | 1 | 2016 |
A Conceptual Design Optimization of Collimator With 181Ta As Neutron Source for Boron Neutron Capture Therapy Based Cyclotron Using Computer Simulation Program Monte Carlo N … JPB Siburian, AW Harto, Y Sardjono Indonesian Journal of Physics and Nuclear Applications 2 (2), 83-90, 2017 | | 2017 |