Follow
Mulya Juarsa
Mulya Juarsa
Sistem Termofluida Reaktor Nuklir, Pusat Riset Teknologi Reaktor Nuklir BATAN - BRIN
Verified email at brin.go.id - Homepage
Title
Cited by
Cited by
Year
Estimation of natural circulation flow based on temperature in the FASSIP-02 large-scale test loop facility
M Juarsa, AR Antariksawan, MH Kusuma, D Haryanto, N Putra
IOP Conference Series: Earth and Environmental Science 105 (1), 012091, 2018
362018
Characteristics of screen mesh wick heat pipe with nano-fluid as passive cooling system
WN Septiadi, N Putra, M Juarsa, IPA Putra, R Sahmura
Atom Indonesia 39 (1), 24-31, 2013
272013
Preliminary study on mass flow rate in passive cooling experimental simulation during transient using NC-queen apparatus
M Juarsa, JH Purba, HM Kusuma, T Setiadipura, S Widodo
Atom Indonesia 40 (3), 141-147, 2014
232014
Simulation of Operational Conditions of FASSIP-02 Natural Circulation Cooling System Experimental Loop
AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra
Jurnal Sains dan Teknologi Nuklir Indonesia (Indonesian Journal of Nuclear …, 2018
212018
Studi eksperimental laju aliran massa air berdasarkan perubahan sudut kemiringan untai pada kasus sirklasi alamiah menggunakan untai sirklasi alamiah (USSA-FT01)
M Juarsa, A GOERITNO, A SUHERI, I SUMIRAT, D SAPTOADI, ...
Jurnal Material dan Energi Indonesia, Jurusan Fisika FMIPA, Universitas …, 2011
212011
Numerical study on natural circulation characteristics in FASSIP-02 experimental facility using RELAP5 code
AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra
IOP Conference Series: Earth and Environmental Science 105 (1), 012090, 2018
182018
Experimental study on transient boiling heat transfer in an annulus with a narrow gap
F Tanaka, M Juarsa, K Mishima, M Murase, T Nagae
Journal of nuclear science and technology 41 (3), 279-284, 2004
152004
Calculation of boiling curves during rewetting of a hot vertical narrow channel
J Zhang, F Tanaka, M Juarsa, K Mishima
The 10th International Topical Meeting on Nuclear Reactor Thermal Hydraulics …, 2003
152003
An experimental analysis on nusselt number of natural circulation flow in transient condition based on the height differences between heater and cooler
M Juarsa, JP Witoko, G Giarno, D Haryanto, JH Purba
Atom Indonesia 44 (3), 123-130, 2018
112018
TRIGA 2000 Research Reactor Thermal-hydraulic Analysis Using RELAP/SCDAPSIM/MOD3. 4
AR Antariksawan, E Umar, S Widodo, M Juarsa, MH Kusuma
International Journal of Technology 8 (4), 698-708, 2017
112017
Passive system simulation facility (FASSIP) loop for natural circulation study
M Juarsa, GBHK GIARNO, D HARYANTO, J PRASETIO
Proceeding of “Seminar Nasional Teknologi Energi Nuklir (SENTEN”. 2016 …, 2016
112016
Experimental study on the effect of gap size to CCFL and CHF in a vertical of narrow rectangular channel during quenching process
M Juarsa, N Putra, WN Septiadi, AR Antariksawan
Annals of Nuclear Energy 72 (Elsevier Ltd), 391 - 400, 2014
112014
Study on Boiling Heat Transfer During Reflooding Process in QUEEN Test Section
M Juarsa, AR Antariksawan, J Prasetyo, I Wahyono, E Sumarno., ...
Proceeding of ICAPP 2005, 15-19, 2005
102005
Preliminary investigation on natural circulation flow using CFD and calculation base on experimental data pre-FASSIP-02
M Juarsa, AR Antariksawan, MH Kusuma, N Putra, PP Moniaga
Journal of Physics: Conference Series 1198 (2), 022073, 2019
92019
Analysis Of The Effect Of Elevation Difference Between Heater And Cooler Position In The Fassip-01 Test Loop Using Relap5
AS Ekariansyah, H Tjahjono, M Juarsa, S Widodo
SIGMA EPSILON-Buletin Ilmiah Teknologi Keselamatan Reaktor Nuklir 19 (1), 2016
82016
Studi Eksperimental Fenomena Sirkulasi Alamiah Aliran Satu-Fasa untuk Pengembangan PRHS Menggunakan Untai FASSIP
M Juarsa
Usulan Penelitian Tahun, 2015
82015
Study on boiling heat transfer under transient cooling in an annulus with a narrow gap
M Juarsa
Master Degree Thesis of Fundamental Energy Science. Kyoto University, 2003
82003
Preliminary investigation of natural circulation stability in FASSIP-01 experimental facility using RELAP5 code
AR Antariksawan, S Widodo, M Juarsa, G Giarno, MH Kusuma, N Putra
AIP Conference Proceedings 2001 (1), 2018
72018
The performance of solar collector CPC (compound parabolic concentrator) type with three pipes covered by glass tubes
YS Gaos, M Yulianto, M Juarsa, N Nurrohman, E Marzuki, D Yuliaji, ...
AIP Conference Proceedings 1826 (1), 2017
72017
Laporan Analisis Keselamatan Eksperimen Post-LOCA menggunakan bagian uji QUEEN-II
M Juarsa
PTRKN BATAN, Serpong, 2007
72007
The system can't perform the operation now. Try again later.
Articles 1–20