Follow
Mukhsinun Hadi Kusuma
Mukhsinun Hadi Kusuma
Centre for Nuclear Reactor Technology and Safety, National Nuclear Energy Agency of Indonesia
Verified email at batan.go.id
Title
Cited by
Cited by
Year
Investigation of the thermal performance of a vertical two-phase closed thermosyphon as a passive cooling system for a nuclear reactor spent fuel storage pool
MH Kusuma, N Putra, AR Antariksawan, FA Imawan
Nuclear Engineering and Technology 49 (3), 476-483, 2017
492017
Passive cooling system in a nuclear spent fuel pool using a vertical straight wickless-heat pipe
MH Kusuma, N Putra, AR Antariksawan, RA Koestoer, S Widodo, ...
International Journal of Thermal Sciences 126, 162-171, 2018
462018
Estimation of natural circulation flow based on temperature in the FASSIP-02 large-scale test loop facility
M Juarsa, AR Antariksawan, MH Kusuma, D Haryanto, N Putra
IOP Conference Series: Earth and Environmental Science 105 (1), 012091, 2018
252018
Vitamin D upregulates endothelin-1, ETBR, eNOS mRNA expression and attenuates vascular remodelling and ischemia in kidney fibrosis model in mice.
N Arfian, MHH Kusuma, N Anggorowati, DB Nugroho, A Jeffilano, ...
Physiological research 67, 2018
192018
Simulation of wickless-heat pipe as passive cooling system in nuclear spent fuel pool using RELAP5/MOD3. 2
MH Kusuma, NSD Putra, S Ismarwanti, S Widodo
International Journal on Advanced Science, Engineering and Information …, 2017
182017
Preliminary study on mass flow rate in passive cooling experimental simulation during transient using NC-queen apparatus
M Juarsa, JH Purba, HM Kusuma, T Setiadipura, S Widodo
Atom Indonesia 40 (3), 141-147, 2014
152014
Simulation of Operational Conditions of FASSIP-02 Natural Circulation Cooling System Experimental Loop
AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra
Jurnal Sains dan Teknologi Nuklir Indonesia (Indonesian Journal of Nuclear …, 2018
122018
Susyadi, FA Imawan, Investigation of the thermal performance of a vertical two-phase closed thermosyphon as a passive cooling system for a nuclear reactor spent fuel storage pool
MH Kusuma, N Putra, AR Antariksawan
Nucl. Eng. Technol 49, 476-483, 2017
122017
Numerical study on natural circulation characteristics in FASSIP-02 experimental facility using RELAP5 code
AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra
IOP Conference Series: Earth and Environmental Science 105 (1), 012090, 2018
112018
TRIGA 2000 Research Reactor Thermal-hydraulic Analysis Using RELAP/SCDAPSIM/MOD3. 4
AR Antariksawan, E Umar, S Widodo, M Juarsa, MH Kusuma
International Journal of Technology 8 (4), 698-708, 2017
112017
Simulation of heat flux effect in straight heat pipe as passive residual heat removal system in light water reactor using RELAP5 Mod 3.2
MH Kusuma, N Putra, S Widodo, AR Antariksawan
Applied Mechanics and Materials 819, 122-126, 2016
112016
Sistem pendingin pasif di kolam penyimpanan bahan bakar bekas nuklir dengan menggunakan pipa kalor= Passive cooling system in nuclear spent fuel storage pool using heat pipe
MH Kusuma
Universitas Indonesia, 2017
82017
Preliminary investigation of natural circulation stability in FASSIP-01 experimental facility using RELAP5 code
AR Antariksawan, S Widodo, M Juarsa, Giarno, MH Kusuma, N Putra
AIP Conference Proceedings 2001 (1), 070003, 2018
62018
Experimental investigation of heat transfer on vertical two-phased closed thermosyphon
MH Kusuma, N Putra, AR Antariksawan, FA Imawan
International Journal of Mechanical and Mechatronics Engineering 9 (10 …, 2017
52017
Effective thermal conductivity of U-shaped heat pipe
MH Kusuma, U Setiorini, TAR Putri, GAR Antariksawan, M Juarsa
IOP Conference Series: Materials Science and Engineering 550 (1), 012004, 2019
42019
Water evaporation rate of RSG-GAS spent fuel storage pool
T Sundari, MH Kusuma, MJ Puspito, D Aji, I Santoso, S Ismarwanti
Journal of Physics: Conference Series 1198 (2), 022009, 2019
42019
Preliminary Experiment of Vertical Straight Wickless-Heat Pipe as Passive Cooling System in Irradiator
K Prayogo, N Putra, MH Kusuma, A Winarta, B Ariantara
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 2019
42019
Preliminary investigation of wickless-heat pipe as passive cooling system in emergency cooling tank
MH Kusuma, N Putra, AR Antariksawan, M Juarsa, S Widodo, T Ardiyati
AIP Conference Proceedings 2001 (1), 020004, 2018
42018
Effect of graphenenano-fluid on heat pipe thermal performance for passive heat removal in nuclear spent fuel storage pool
A Rosidi, N Putra, MH Kusuma
IOP Conference Series: Earth and Environmental Science 105 (1), 012030, 2018
42018
Investigation on vertical straight wickless-heat pipe as gamma irradiator passive cooling system
K Prayogo, N Putra, MH Kusuma, NA Abdullah, B Ariantara
AIP Conference Proceedings 2255 (1), 020040, 2020
32020
The system can't perform the operation now. Try again later.
Articles 1–20